ER15-JSI-02
From ERwiki
(Difference between revisions)
(→DOCUMENTATION) |
Samo Gerksic (Talk | contribs) |
||
Line 68: | Line 68: | ||
* [[Media:ERMeetingMar2015_AP.pdf | Design of a realistic feedback+feedforward control scheme able to manage the whole plasma pulse - A. Pironti (Mar 25th 2015)]] | * [[Media:ERMeetingMar2015_AP.pdf | Design of a realistic feedback+feedforward control scheme able to manage the whole plasma pulse - A. Pironti (Mar 25th 2015)]] | ||
* [[Media:ARIOLA_KOM_ER.pdf | Simultaneous control of modes with multiple toroidal periodicity in tokamak plasmas - M. Ariola (Mar 25th 2015)]] | * [[Media:ARIOLA_KOM_ER.pdf | Simultaneous control of modes with multiple toroidal periodicity in tokamak plasmas - M. Ariola (Mar 25th 2015)]] | ||
+ | |} | ||
+ | |||
+ | {| width="100%" cellpadding="2" cellspacing="5" style="vertical-align:top;background-color:#A1F7A6" | ||
+ | ! <p style="margin:0;background-color:#A4FF75;font-size:120%;font-weight:bold;border:1px solid #000000;text-align:left;color:#000;padding:0.2em 0.4em;">Deliverables</p> | ||
+ | |- | ||
+ | |style="color:#000"| | ||
+ | * [[Media:FMPCFMPC_D1_v2.pdf | D1: A set of reduced-order models and a state-estimation scheme for ITER plasma shape and current control ]] | ||
|} | |} | ||
|} | |} | ||
</span> | </span> | ||
<span> | <span> |
Revision as of 14:34, 28 July 2015
Fast Model Predictive Control for Magnetic Plasma Control
Principal Investigator:
Samo Gerksic (IJS)
Contributors:
Marco Ariola (CREATE)
Alfredo Pironti (CREATE)
Boštjan Pregelj (IJS)
Andrej Debenjak (IJS)
Participating institutions:
Institut "Jožef Stefan", Ljubljana, Slovenia
Consorzio CREATE, Naples, Italy
COSYLAB, Ljubljana, Slovenia
Page last edited on 28-7-2015
PROJECT OBJECTIVES
The main project objectives are:
- O1 -> Review possible approaches of complexity reduction for fast Model Predictive Control (MPC) suitable for Plasma Current and Shape Control (PSC) and possibly to Resistive Wall Modes (RWM) control
- O2 >> Implement the most appropriate fast MPC method
- O3 >> Adapt plasma models for use in MPC and prepare a set of models in different operation points of an ITER scenario, in order to assess robustness
- O4 >> Develop a suitable state-estimation technique
- O5 >> Apply fast MPC to PSC control
- O6 >> Evaluate fast MPC performance and robustness to disturbances and variation of local dynamics in comparison to existing approaches
- O7 >> Evaluate the applicability of fast MPC to RWM control
DOCUMENTATION